Sinocare Blood Glucose Meter Safe-Accu2
৳ 1,200 ৳ 1,100
AFFORDABLE PRICE FOR DAILY USE: Low Cost Testing Strips Specifications FAD-GDH System
Blood Sample needs only 0.6ul
Test Range: 20 – 600mg/dL
Test Time: 10s
Expiry Date: 24 mos
Memory: 200 results
Battery lifetime: above 1000times
Triple sense technology – Accurate results in 9 seconds
Simple to operate – Automatically turn on when you insert the test strip into the strip port
High-contrast LCD display – Large reading in a small, discreet meter
Strong memory – 7, 14 and 28 day averages with 200 test results
FAD-GDH system : It is not easily affected by oxygen molecule in the blood.
User-friendly operation system: no coding & automatic test strip ejectionin the management of diabetes.
Sinocare Blood Glucose Meter Safe-Accu2
Product Description:
AFFORDABLE PRICE FOR DAILY USE: Low Cost Testing Strips Specifications FAD-GDH System
Blood Sample needs only 0.6ul
Test Range: 20 – 600mg/dL
Test Time: 10s
Expiry Date: 24 mos
Memory: 200 results
Battery lifetime: above 1000times
Triple sense technology – Accurate results in 9 seconds
Simple to operate – Automatically turn on when you insert the test strip into the strip port
High-contrast LCD display – Large reading in a small, discreet meter
Strong memory – 7, 14 and 28 day averages with 200 test results
Blood volume | 0.6μL |
Sample type | Capillary whole bloodyenous whole blood |
Calibration | Plasma equivalent |
Measuring time | 5s |
Meter storage/transportation condition | -20℃~55℃ |
Dimension | 84*60*26(mm) |
Weight | 73.5g, with battery |
Power source | 3V DC, 50mA, 2 AAA alkaline batteries |
Memory | 10 blood glucose test results |
Operating condition | 10℃~35℃; ≤80% RH |
Construction | Hand-held |
Measurement units | mg/dL or mmol/L |
Measurement range | 20~600 mg/dL or 1.1~33.3mmo/L |
Shelf life | 10 years(estimated by test 7 times per day). During use, user should maintain the product refer to this user manual’s requirements. |
Performance Characteristics
Accuracy: 95% test result of Safe AQ meet the requirement below:
Concentration Range | Bias% |
---|---|
<5.5 mmol/L(100 mg/dL) | Within±0.83 mmol/L(15 mg/dL) |
25.5 mmol/L(100mg/dL) | Within ± 15% |
Precision: test result of Safe AQ Smart meet the requirement below:
Concentration Range | Require ment |
---|---|
<5.5 mmol/L(100 mg/dL) | SD<0.34mmol/L(6.0mg/dL) |
25.5 mmol/L(100mg/dL) | CV<6.0% |